Overview
This specification defines the performance characteristics for a class Ⅱ adapter, single-phase 12.0 watts. Single output level power supply.
◆ Simple design philosophy.
◆ Reliability level of 50K hours MTBF @ 25° C (rated input voltage and using the Telcordia SR-332 issue 3 method).
◆ DC output voltage must be Safe Extra Low Voltage (SELV) & Limited Power as defined by IEC62368-1.
◆ The maximum room ambient temperature (Tmra), as mentioned in clause B.1.6 and B.2.6 of IEC62368-1, for the external power supply is 40°C.
◆ Cooling: natural convection.
|
Input & Output Requirements
INPUT REQUIREMENTS | |
Rated input voltage | 100-240Vac |
Operating range | 90-264Vac |
Rated input frequency | 50/60Hz +/- 3Hz |
Rated input current | 0.4A max. |
Power consumption (no-loading) | 0.1W max. |
Primary current protection | An adequate internal fuse on the AC input line is provided. |
Configuration | 2 Conductor |
AC Inrush Current |
No damage shall be occurred and the input fuse shall not be blown up nominal input voltage full load 25°C cold start. |
OUTPUT REQUIREMENTS | |
Nominal DC output voltage | +12.0V |
Minimum load current | 0.01A |
Rating load current | 1.0A |
Peak load current | / |
Rating output power | 12.0W |
Line regulation | The line regulation is less than ±5% while measuring at rated load and +/-10% of input voltage changing. |
Load regulation | The load regulation for +12.0V is less than ±5%, at measured output load from 10% to 100% rated load. |
Peak load regulation | The peak load regulation for +12.0V is less than / , at measured output load from 30% to 100% rated load. |
Ripple and noise | 120 mVp-p |
Add 0.1uF/50V ceramic capacitor and 10uF/50V aluminum electrolytic capacitor across the output terminal. Measured with 20MHz Bandwidth Oscilloscope. | |
Average efficiency | 82.96% minimum |
115V/60Hz and 230V/50Hz, output current from 100%, 75%, 50%, 25%. | |
Turn on delay time | 3000 mS max. at nominal input AC voltage and full load |
Rise time | The supply shall have a start-up rise time of less than 20mS to rise to within regulation limits for all DC outputs. |
Hold up time | 8 mS minimum at nominal input 100V AC minimum voltage and full load. |
Output over-shoot | Less than 7% of nominal voltage value. |
LED indication function | / |
Protection function | Short-circuit protection:The adapter shall not be damaged by short the DC output to Ground. The adapter shall resume normal operation when a short circuited fault condition is removed. |
Over current protection:The output shall be protected against the over current conditions. |